TrentoPProject

TrentoPProject designs a storm sewer network. It takes the layout of the pipes, the areas they drain and the ground elevation at their junctions, and gives each pipe its design discharge, its commercial diameter, its slope and the depth of its excavation. TrentoPCalibration then verifies an existing network, or the designed one, for a given rain.

The model is the geomorphological model of TrentoP. Each drained area is a linear reservoir, and the water travels through the pipes with the delay of a kinematic wave. The pipes are designed one after the other, from the head pipes down to the outlet. Each pipe gets the peak discharge of the rain from the rainfall curve whose duration maximizes it, and the smallest commercial diameter that carries that discharge at the design fill degree while staying self-cleaning. The formulas are in the notes of the reference below.

Details

The project (design) mode of TrentoP, a geomorphological model of urban storm drainage. The pipes are designed from the head pipes down to the outlet, each for the peak discharge of the rain duration that maximizes it.

Each drained area is a linear reservoir, with residence time k = 60·c·(A/100)^α / (φ^b·s^γ) minutes, where c is the AveResT field, A the drained area in ha, φ the runoff coefficient and s the average slope of the area in %, while α, b and γ are the parameters Exponent of the basin extension, Exponent of the influx coefficent and Exponent of the average ponderal slope. The inflow is distributed along the pipe, and the water travels in the pipes with a delay L/u, where u is the mean velocity in the pipe times the Celerity factor, found iteratively. The rain comes from the rainfall curve h = a·t^n, with h in mm and t in hours.

A circular pipe gets the smallest commercial diameter that carries the discharge at the design Fill degree with a bottom shear stress of at least the Tangential bottom stress, which keeps it self-cleaning. Where the ground, or the pipe minimum slope, is steeper than the slope this needs, the pipe follows it and the diameter is designed again. Downstream, the diameters never get smaller. The excavation starts at the ground elevation of the upstream junction, minus the Minimum excavation depth and the outer diameter.

Preparing the data

Both modules read a spatial database, given in inDatabase: a GeoPackage (.gpkg) or H2GIS (.mv.db) file, or a PostGIS database, as jdbc:postgresql://host:port/database, with pUser and pPassword. It holds layers and tables with fixed names, in a projected reference system in meters:

Layer or table

Content

Project

Calibration

network_project

the pipes, as lines

✓

network_calibration

the pipes of an existing network, with their diameters

✓

areas

the areas drained by the pipes, as polygons

✓

✓

junctions

the junctions at the ends of the pipes, as points

✓

✓

parameters

the parameters of the model

✓

✓

diameters

the commercial diameters

✓

The results are written into the same database: the designed pipes as network_project_output, the verified ones as network_calibration_output. Running a module again replaces them.

Start from TrentoPProjectFilesGenerator: it creates the database with the empty layers, with all their fields, the parameters with their defaults and an example series of diameters. Then draw the pipes, areas and junctions in a GIS, fill their fields and the needed parameters. The project and the calibration of a network can share one database.

The pipes

Draw a line for each pipe, between two junctions. The pipes are connected by their ends: the topology of the network is built from the geometries, starting from the outlet pipe given by pOutPipe and following the pipes whose ends are within 0.1 m of each other, so snap the ends while drawing. The direction of the lines does not matter, since the end at the higher junction is the upstream one. At most Max number of junction pipes can drain into the end of a pipe.

The fields of the pipes:

Field

Type

Content

ID

integer

the unique number of the pipe

Runoff

real

the runoff coefficient of its area, from 0 to 1

AveResT

real

the coefficient c of the residence time of its area, the mean residence time per unit area, in h/ha (see below)

ks

real

the roughness of Gauckler-Strickler, in m^(1/3)/s

AveSlope

real

the average slope of its area, in %

MinSlope

real

the minimum slope of the pipe, in % (project only)

Section

integer

the section: 1 circular, 2 rectangular, 3 trapezoidal (project only)

diameter

real

the inner diameter of the existing pipe, in cm (calibration only)

dryArea

real

optional: the part of the area that drains into the pipe, from 0 to 1

dryArea is not created by the generator: add it to the layer when only a part of some areas drains into the network, and then give it a value for every pipe. The IDdrain field, the pipe each pipe drains into, is not read: it is computed from the geometries and written in the output.

AveResT and Runoff are the two parameters that set how much water reaches the network, and how fast. The original manual of TrentoP gives this advice for them:

  • AveResT is, in practice, the calibration parameter of the model, more than a physical quantity: set it from a measured event of the network when there is one, else from experience, and try a few values around the likely one. From the Italian test basins of TrentoP it is between 0.3 and 1 h/ha, around 0.38. It gets smaller as the slope of the area grows, and as the share of impervious surface grows.

  • Runoff depends on the surfaces of the area, but also on the rain, and changes from event to event. With a measured event, set it so that the volumes match; without, take it from an empirical formula, and try a few values.

The areas

Draw, for each pipe, the polygon of the area that drains into it, with the ID of the pipe: every pipe needs exactly one area. Its surface, in ha, is the area of the polygon. The inflow of the area is distributed along the pipe.

The junctions

Put a point at each end of every pipe, within 0.1 m of it, and give it the ground elevation in the elev field, in m. Each end needs exactly one point, so two junctions can’t be closer than 0.1 m. The elevations can be taken from an elevation model with RasterCatToFeatureAttribute, with fNew = "elev". The other fields of the junctions are not used.

The parameters

The table parameters has a row for each parameter, with its name, the one in the tables below, its value, and, for reference, its unit, default_value, min_value and max_value. The generator fills the value of the optional parameters with their default, and leaves the needed ones, the ones without a default, empty: give them a value. A parameter without value, or missing, takes its default.

The parameters of the design:

Name

Unit

Default

Content

Coefficient of the pluviometric curve

mm/h^n

a of the rainfall curve h = a·t^n, with t in hours

Exponent of the pluviometric curve

-

n of the rainfall curve, from 0.05 to 0.95

Tangential bottom stress

N/m²

the shear stress at the bottom that keeps the pipes self-cleaning

Fill degree

-

the design fill degree, water depth over diameter, up to 0.99

Align mode

-

at the junctions, 0 aligns the free surfaces by changing the depth of the pipes, 1 aligns them with steps in the bottom

Time step for simulation

min

0.25

the time step of the search of the peak discharge, from 0.015 to 0.5

Minimum Rain Time step

min

5

the shortest rain duration of the search, at least 5

Maximum Rain Time step

min

60

the longest rain duration of the search, at least 30

Minimum excavation depth

m

1.2

the depth of the top of the pipes under the ground

The other parameters, which usually keep their default:

Name

Default

Content

Max number of junction

4

the most pipes that can drain into the end of a pipe, up to 6

Celerity factor

1

the celerity of the wave over the mean velocity, from 1 to 1.6

Exponent of the basin extension

0.3

α, the exponent of the area in the residence time

Exponent of the influx coefficent

0.4

b, the exponent of the runoff coefficient in the residence time

Exponent of the average ponderal slope

0.2

γ, the exponent of the slope in the residence time

Minimum discharge in a pipe

1

the first guess of the discharge, in l/s

Minimum fill degree

0.01

the lowest fill degree, up to 0.1

Maximum fill degree

6.28319

the fill of a full pipe, as the angle of its wetted perimeter in radians: 2π is the whole pipe

Base to height

1

the base over the height of rectangular and trapezoidal sections

Max bisection number, Precision, Tolerance, Accuracy (bisection mode)

40, 0.001, 0.0001, 0.005

the iterations and accuracy of the numerical solutions

The diameters

The table diameters lists the commercial diameters of circular pipes, one per row, with their diameter and thickness, both in cm. The generator fills it with an example series of PVC pipes, from 14 to 100 cm: change it to the pipes that will be used. The diameter is the inner one, used for the hydraulics; the thickness adds to the excavation. Check the unit: a list in mm is read as cm, and gives pipes ten times too large.

Parameters

Designs a storm sewer network: the design discharge, diameter, slope and depth of each pipe.

Toolbox folder: Hydro-Geomorphology
Status: Draft
Keywords: Sewer network, Storm water, Urban hydrology
Authors: Daniele Andreis, Rigon Riccardo, David tamanini, Andrea Antonello, Silvia Franceschi
Class: org.hortonmachine.modules.TrentoPProject

Inputs

Parameter

Type

Unit

Default

Description

inDatabase

file

The database of the network, with the layers network_project, areas and junctions and the tables parameters and diameters: a GeoPackage (.gpkg) or H2GIS (.mv.db) file, or a PostGIS database, as jdbc:postgresql://host:port/database. The designed network is written into it, as the layer network_project_output.

pUser

String

The optional user of the database.

pPassword

String

The optional password of the database.

pOutPipe

Integer

-

The ID of the outlet, the last pipe of the network.

References

  • Rodríguez-Iturbe, I., Valdés, J. B. (1979). The geomorphologic structure of hydrologic response. Water Resources Research, 15(6), 1409-1420.

Example

The example designs a small network of 25 pipes, which drain 2 ha to the outlet pipe 31. Its data are in the GeoPackage docs/manual/modules/maps/data/sewer_project.gpkg, with the elevation model of the area, dtm_sewer.tif, at 1 m:

import org.hortonmachine.modules.TrentoPProject

// the folder with the sample data: change it to yours
var folder = "/data/sewer/"

// the GeoPackage holds the layers network_project, areas and junctions, and the
// tables parameters and diameters
var project = new TrentoPProject()
project.inDatabase = folder + "sewer_project.gpkg"
project.pOutPipe = 31
project.process()

// the designed network is written into the same GeoPackage, as network_project_output
The designed network, colored by the diameter of the pipes, in cm: 14 cm in the head pipes, up to 40 cm in the collector down to the outlet.

The designed network, colored by the diameter of the pipes, in cm: 14 cm in the head pipes, up to 40 cm in the collector down to the outlet, at the bottom left.

The design discharge at the outlet is 285 l/s. The output layer network_project_output has, besides the input fields and IDdrain:

Field

Content

discharge

the design discharge, in l/s

cUdomet

the discharge per unit area, in l/s/ha

resTime

the residence time of the area, in minutes

tP

the rain duration that gives the peak, in minutes

t_Qmax

the time of the peak, in minutes

mean_speed

the mean velocity, in m/s

pipeslope

the slope of the pipe, in %

diameter

the diameter, in cm

empty_deg

the fill degree, water depth over diameter

DownDepth, upDepth

the elevation of the bottom of the excavation, in m: despite the names, DownDepth at the upstream end and upDepth at the downstream end

DoFreeSurf, UpFreeSurf

the elevation of the free surface, in m, likewise at the upstream and downstream end

totArea

the area drained by the pipe and all the pipes upstream, in ha

totlength, meanlength, varLength

the total length of the network upstream, the mean length of its pipes, in m, and its variance