TrentoPCalibration¶
TrentoPCalibration verifies a storm sewer network whose pipes are known: for a rain, it gives the discharge and the fill degree of each pipe in time. It uses the same geomorphological model as TrentoPProject, which designs a new network.
The rain is either a time series of measured intensities, or a rain generated from the rainfall curve. The slope of each pipe is the slope between the ground elevations of its two junctions.
Warning
When a pipe fills up completely, the simulation stops, with a warning that names the pipe. The pipes downstream of it, which were not computed yet, keep a discharge of 0: check the warnings, and a fill degree that reaches its maximum, before reading the results.
Details¶
The calibration (verification) mode of TrentoP: the diameters of the pipes are known, and the module computes the hydrographs of the network for a rain, with the same geomorphological model as TrentoPProject.
The rain is either a time series of intensities, in mm/min, or it is generated from the rainfall curve, when the Coefficient of the pluviometric curve and Exponent of the pluviometric curve are in the parameters file. A generated rain lasting tp has the constant intensity a·tp^(n-1), so that it brings the depth a·tp^n of the curve. With a maximum rain duration, the durations from the Minimum Rain Time step up to it, in steps of the time step, are tried, and the one that gives the highest discharge is kept. Without it, a single rain lasting the whole simulation is used.
The pipe slopes are the slopes between the elevations of the junctions at their ends. When a pipe fills up completely, the simulation stops with a warning: the pipes downstream of it, not yet computed, keep a discharge of 0.
Preparing the data¶
The database holds the layers network_calibration, areas and junctions and the table parameters, prepared as described for TrentoPProject, and created with TrentoPProjectFilesGenerator in Calibration mode. To verify a designed network, copy its network_project_output layer to network_calibration: it has all the fields needed. The pipes have the field diameter, the inner diameter of the existing pipes in cm, instead of MinSlope and Section.
All the pipes are taken as circular: other sections, as egg-shaped or box sections, can’t be verified. Each pipe needs a drop between its two junctions, since its slope comes from their elevations: a flat pipe can’t be computed. For the verification of a real network, the elevations of the junctions are best the ones of the pipe bottoms, when they are known, rather than the ones of the ground.
The verification is where AveResT and Runoff are calibrated: with a measured rain and the discharges measured in the network, see the advice on them in TrentoPProject.
In the table parameters, the time step, the duration of the simulation and the maximum rain duration can be given instead of the arguments of the module, which win when both are set:
Name |
Unit |
Content |
|---|---|---|
|
min |
the time step of the generated rain and of the results, the argument |
|
min |
the duration of the simulation, the argument |
|
min |
the maximum rain duration, the argument |
|
min |
the shortest rain duration of the search, by default 5 |
|
mm/h^n |
a of the rainfall curve, to generate the rain |
|
- |
n of the rainfall curve, to generate the rain |
The other parameters are the optional ones of TrentoPProject, from the Celerity factor to the exponents of the residence time.
The rain¶
With the two parameters of the rainfall curve, the rain is generated, as in TrentoPProject. A rain lasting tp has the constant intensity a·tp^(n-1), so that it brings the depth a·tp^n of the curve: shorter rains are more intense, longer ones bring more water. With a maximum rain duration, the durations from the Minimum Rain Time step up to it, in steps of the time step, are tried, and the one that gives the highest discharge is kept; the module returns it as outTpMax. The time step is also the shortest rain that can be tried. Without a maximum rain duration, a single rain lasting the whole simulation is used.
Without the rainfall curve, the rain is read from inRain, an OMS time series of intensities in mm/min, at a constant time step, which is also the time step of the results:
@T, "rain data"
DateFormat,yyyy-MM-dd HH:mm
@H, time,rain
,2020-06-01 12:00,0.5
,2020-06-01 12:05,0.5
,2020-06-01 12:10,0.4
Parameters¶
Verifies an existing storm sewer network: the discharge and the fill degree of each pipe in time, for a given rain.
Toolbox folder: Hydro-Geomorphology
Status: Draft
Keywords: Sewer network, Storm water, Urban hydrology
Authors: Daniele Andreis, Rigon Riccardo, David tamanini, Andrea Antonello, Silvia Franceschi
Class: org.hortonmachine.modules.TrentoPCalibration
Inputs
Parameter |
Type |
Unit |
Default |
Description |
|---|---|---|---|---|
|
file |
The database of the network, with the layers network_calibration, areas and junctions and the table parameters: a GeoPackage (.gpkg) or H2GIS (.mv.db) file, or a PostGIS database, as jdbc:postgresql://host:port/database. The verified network is written into it, as the layer network_calibration_output, with the maximum discharge (qmax, l/s), its time (t_qmax, minutes) and the maximum fill degree (fillmax) of each pipe. |
||
|
String |
The optional user of the database. |
||
|
String |
The optional password of the database. |
||
|
Integer |
- |
The ID of the outlet, the last pipe of the network. |
|
|
Integer |
minutes |
The time step of the generated rain and of the results (default: the Hydraulic time step of the parameters). With a rain file, the time step of the file is used. |
|
|
Integer |
minutes |
The duration of the simulation (default: the Maximum simulation time step of the parameters, or 120). |
|
|
Integer |
minutes |
The maximum rain duration (default: the Maximum Rain Time step of the parameters). With the rainfall curve, the rain durations from the Minimum Rain Time step up to it are tried, with a rain file only the rain up to it is used. |
|
|
CSV file |
The rain intensities, in mm/min, used when the rainfall curve is not in the parameters. |
Outputs
Parameter |
Type |
Unit |
Description |
|---|---|---|---|
|
output file |
The discharge of each pipe in time, in l/s. |
|
|
output file |
The fill degree of each pipe in time. |
|
|
Integer |
minutes |
The duration of the rain of the results: the one that gives the maximum discharge, when it is searched. |
References
Rodríguez-Iturbe, I., Valdés, J. B. (1979). The geomorphologic structure of hydrologic response. Water Resources Research, 15(6), 1409-1420.
Example¶
The example verifies an existing network of 25 pipes, from 12 to 40 cm, which drain 2 ha to the outlet pipe 31. Its data are in the GeoPackage docs/manual/modules/maps/data/sewer_calibration.gpkg, and all the times are in its parameters: a time step of 5 minutes, 120 minutes of simulation and rains from 5 to 60 minutes:
import org.hortonmachine.modules.TrentoPCalibration
// the folder with the sample data: change it to yours
var folder = "/data/sewer/"
// the GeoPackage holds the layers network_calibration, with the diameters of the
// existing pipes, areas and junctions, and the table parameters: the rainfall curve,
// the time step, the duration of the simulation and the maximum rain duration are
// all taken from the parameters
var calibration = new TrentoPCalibration()
calibration.inDatabase = folder + "sewer_calibration.gpkg"
calibration.pOutPipe = 31
calibration.outDischarge = folder + "sewer_discharge.csv"
calibration.outFillDegree = folder + "sewer_filldegree.csv"
calibration.process()
// the verified network is written into the same GeoPackage, as network_calibration_output
println "Critical rain duration: " + calibration.outTpMax + " minutes"
The network is small and quick, so the shortest rain, 5 minutes, the most intense, gives the highest discharge. The output layer network_calibration_output has, besides the input fields, the maximum discharge qmax, in l/s, its time t_qmax, in minutes from the start, and the maximum fill degree fillmax, water depth over diameter. No pipe fills up: the fullest reach 0.55.
The maximum fill degree of the pipes, for the critical rain of 5 minutes: the loop of pipes at the top and the collector down to the outlet, at the bottom left, are the fullest.¶
The discharge of each pipe in time is written to outDischarge, a table with the time, in minutes, and a column for each pipe, and the fill degree likewise to outFillDegree.
The discharge, in l/s, of the outlet pipe 31, of the collector pipe 27 and of the head pipe 1, for the critical rain of 5 minutes: the peak at the outlet, 227 l/s, comes right after the end of the rain, and the network empties in about half an hour.¶